AT/SC: PU-23-01 Truck won’t start/Active Code on Chassis ECM

System: Electrical

Affected Tanks: 621G (SK8SC-005 to -009), 725 Articulated Truck (SN SK5AT-009 to -0016), 730 Articulated Truck (SN SK6AT-003 to -0019), 740 Articulated Truck (SN SK8AT-005 to -0010), 745 Articulated Truck (SN SK9AT-001 and SK9AT-004)

Reason: Truck will not start. Active Code on Chassis ECM (Shift hoist voltage high); Spray King IFM controller not broadcasting voltage to shift hoist circuit. Failure: Possible water intrusion at IFM power and ground connector causing failure (Con17)

Completion: Inspect, replace connector, pins, and install wire seals. Reuse two cavity plugs.

Product Update: 

Parts needed:

Qty 1:  1745078-1 Connector

Qty 4:  3-00905-01 Wire Seal

Qty 2: 3-00575-01 16ga terminal

Qty 2: 3-00574-01 14ga terminal

Crimping tool needed. Manufacture-ABN part# 6231

Download full product update document for specific instructions. 